Forklift series lithium iron phosphate battery pack parameters |
Serial number |
Project |
Series parameters |
Remark |
|
|
12V |
24V |
48V |
80V |
|
1 |
Cell material type |
Lithium iron phosphate |
|
2 |
Nominal voltage (V) |
12.8 |
25.6 |
51.2 |
83.2 |
|
3 |
Working voltage range (V) |
10-14.6 |
20-29.2 |
40-58.4 |
65-94.9 |
|
4 |
Nominal capacity (AH) |
Can be customized within the range of 50~700 |
|
5 |
Charging cut-off voltage (V) |
14.6 |
29.2 |
58.4 |
94.9 |
|
6 |
Discharge cut-off voltage (V) |
10 |
20 |
40 |
65 |
|
7 |
Standard charging current (A) |
1C, 25℃ ambient condition, constant current charging |
|
8 |
Standard discharge current (A) |
1C, 25℃ ambient condition, constant current charging |
|
9 |
Discharge working temperature range (℃) |
-20~55℃ |
|
10 |
Charging temperature range (℃) |
-5~55℃ |
|
11 |
Storage ambient temperature (℃) |
(-20~55, short term, within 1 month; 0~35, long term, within 1 year) |
|
12 |
Storage environment humidity (RH) |
5%~95% |
|
13 |
Working environment humidity (RH) |
≤85% |
|
14 |
Normal temperature cycle life |
25℃, cycle life 3500 times (>80% rated capacity), 1C charge and discharge rate |
|
15 |
High temperature cycle life |
45℃, cycle life 2000 times (>80% rated capacity), 1C charge and discharge rate |
|
16 |
Room temperature self-discharge rate (%) |
3%/month, 25℃ |
|
17 |
High temperature self-discharge rate (%) |
5%/month, 45℃ |
|
18 |
High temperature discharge performance |
≥95% (the battery is charged according to the standard charging mode (the battery is charged to 3.65V at 1C constant current and constant voltage, and the cut-off current is 0.05C; at 45±2C, it is discharged at 1.0C constant current to the minimum discharge voltage of 2.5V) |
|
19 |
Low temperature discharge performance |
≥70% (the battery is charged according to the standard charging mode (the battery is charged to 3.65V at 1C constant current and constant voltage; at -20±2C, it is discharged at 0.2C constant current to 2.5V) |
|
20 |
Cabinet size |
Can be customized according to customer requirements |
|
21 |
Control System |
BMS program |
|